Focused on Asia Pacific · Connected to global practice
MICROGRID CENTRE · TOPIC PLATFORM

Training

Understand how batteries, pumped hydro, air, flywheels, capacitors, thermal and hydrogen storage work. Compare service boundaries, site constraints and lifecycle evidence before choosing an architecture.

This centre covers electrochemical, mechanical, electrical, thermal and chemical storage. The three existing lessons, evidence checklist and procurement calculator specifically address stationary batteries. Microgrid dispatch and VPP participation remain linked to their existing topic paths.

Storage extends beyond batteries

Start with the principles and selection of batteries, pumped hydro, compressed/liquid air, flywheels, capacitors, heat and hydrogen. Training contains nine lessons; the three original lessons and procurement tool form a battery-specific path.

Read the full technical chapter and cases

Topic training and membership

Data centres, VPP, energy storage and heat–power each offer nine lessons in three modules. The three lessons in each first module are free. Modules two and three are included in monthly and annual Intelligence membership, with technical explanations, figures, engineering cases, exercises and worked answers: 24 member lessons across four topics.

The existing price remains US$19.90 monthly or US$199 annually. One subscription includes all four topics; active members do not buy courses separately. Knowledge libraries, technology overviews, existing topic calculators, data checklists and self-service diagnostics remain free.

Member lessons are available during an active subscription. Topic courses are currently in English and Simplified Chinese. Custom project analysis, design review and personal consulting require a separate scope and quotation; they are not included in the subscription.

Account and membership plans →

This pathway contains three modules and nine lessons. Each includes technical explanations, a diagram, a teaching case, independent exercises and worked answers. Complete each module output before progressing; existing battery lesson URLs are preserved.

ES1 · Storage fundamentals and physical technologies

Module output: Prepare a service specification and distinguish energy, machine power, site resources and charging constraints.

MODULE LESSON 1

ES1.1 · Storage services and technology selection

A storage project buys a time-dependent service, rather than an inventory alone. Specify the net power at a named meter, uninterrupted duration, response delay, recovery window and protected reserve. Heating, cooling and electrical backup are different services even when all quantities are expressed in MWh.

  • Calculate the event energy.
  • Identify the first failed constraint for each device.
  • Specify the next evidence request.
Study free lesson
MODULE LESSON 2

ES1.2 · Pumped hydro and hydraulic design

Reservoir hydro uses natural inflow; pumped storage consumes electricity to restore water elevation. A combined plant may do both, but its natural-inflow generation is not energy recovered from charging. Define upper and lower operating levels, usable volume, pumping intake and generation outlet before calculating storage.

  • Calculate potential and electrical energy.
  • Can it supply 5 MW for six hours?
  • What average charging power is needed?
Study free lesson
MODULE LESSON 3

ES1.3 · Air storage and thermal process boundaries

Compressed air inventory is defined by pressure, temperature, mass and the allowed operating window. A pressure vessel volume alone is not usable electricity. Compression releases heat; expansion cools the gas. The heat balance and minimum pressure determine how much electricity can be returned.

  • Explain why 70% and 60% are not directly comparable RTE claims.
  • Calculate A output divided by total stated energy input.
  • Can either commit 5 MW?
Study free lesson

ES2 · Battery engineering, procurement and acceptance

Module output: Prepare a common AC duty, warranty comparison and acceptance evidence register.

MODULE LESSON 1

ES2.1 · What a battery system actually delivers

A storage quotation often lists MW and MWh together, but they answer different questions. This lesson follows energy from the cell to the service meter and separates component ratings from a whole-system operating promise. You will build a duty sheet before deciding whether a battery is large enough.

  • Explain the roles of the battery, BMS, PCS, auxiliaries and supervisory control.
  • Reconcile DC nameplate, retained capacity, SOC-window energy and net AC delivery.
  • Check power and duration independently and identify missing operating evidence.
View member lesson
MODULE LESSON 2

ES2.2 · Procurement, warranties and comparable quotations

A low price and a long warranty can conceal incompatible service boundaries. This lesson turns a quotation into a traceable set of promises and tests calendar limits against the energy the owner actually plans to deliver.

  • Build one common procurement scope across suppliers.
  • Interpret calendar and throughput conditions without predicting failure.
  • Create an exception register and an acceptance/remedy question list.
View member lesson
MODULE LESSON 3

ES2.3 · Acceptance, safety and lifecycle evidence

A factory test, a commissioning record and a reliable operating service cover different parts of the evidence chain. This lesson develops a practical handover method: define the claim, specify the test and preserve the configuration, limitations and responsible party.

  • Distinguish component tests, site acceptance and integrated service verification.
  • Explain how safety evidence and operational capability support separate decisions.
  • Create a lifecycle record with meaningful review triggers.
View member lesson

ES3 · Complementary storage and project integration

Module output: Prepare separate service ledgers and a justified technology or hybrid shortlist with unresolved actions.

MODULE LESSON 1

ES3.1 · Fast storage and long-duration hydrogen

Fictional paired duties: 2 MW for 15 seconds, and 1 MW for 24 hours. A hydrogen route uses 33.3 kWh/kg LHV, 50% net electrical conversion and 50 kWh/kg electrolysis electricity, excluding compression.

  • Calculate both service energies.
  • Calculate hydrogen inventory and electrolysis electricity for the long task.
  • Explain why neither a fast device nor a fuel inventory establishes the complete service.
View member lesson
MODULE LESSON 2

ES3.2 · Thermal storage and hybrid service design

Fictional island: electrical critical load 0.5 MW for four hours and useful heat 2 MW_th for six hours. A tank advertises 12 MWh_th. A battery has 2 MWh usable AC but no validated transfer-time evidence.

  • Prepare separate heat and electricity ledgers.
  • Explain why nominal tank energy is insufficient evidence.
  • Assign duties in a hybrid architecture.
View member lesson
MODULE LESSON 3

ES3.3 · Multi-technology project workshop

Fictional six-hour duty: 5 MW net AC. Hydro offers 23.1625 MWh AC and a 5 MW output limit. Battery offers 32 MWh usable AC but a 4 MW converter limit. A proposed hybrid has no agreed dispatch or network evidence.

  • Identify each standalone failure.
  • Can adding nameplates prove hybrid feasibility?
  • Prepare the next review actions.
View member lesson

Sources and review date

Reviewed 26 October 2026. Text, diagrams and exercises are original. All numerical cases use stated teaching assumptions, rather than site measurements or manufacturer commitments. These primary sources support the technical background; verify their applicability to each project.

[S1] DOE FEMP · BESS Procurement Checklist ↗
Early procurement questions and scope.

[S2] DOE FEMP · Lithium-ion BESS Technical Specifications ↗
Customisable procurement template, not a local approval.

[S3] DOE · Energy Storage Safety Strategic Plan ↗
Lifecycle safety research and deployment context.

[S4] Sandia · Energy Storage Safety and Reliability ↗
Testing, failure and degradation background.