Understand how batteries, pumped hydro, air, flywheels, capacitors, thermal and hydrogen storage work. Compare service boundaries, site constraints and lifecycle evidence before choosing an architecture.
This centre covers electrochemical, mechanical, electrical, thermal and chemical storage. The three existing lessons, evidence checklist and procurement calculator specifically address stationary batteries. Microgrid dispatch and VPP participation remain linked to their existing topic paths.
Storage extends beyond batteries
Start with the principles and selection of batteries, pumped hydro, compressed/liquid air, flywheels, capacitors, heat and hydrogen. Training contains nine lessons; the three original lessons and procurement tool form a battery-specific path.
Data centres, VPP, energy storage and heat–power each offer nine lessons in three modules. The three lessons in each first module are free. Modules two and three are included in monthly and annual Intelligence membership, with technical explanations, figures, engineering cases, exercises and worked answers: 24 member lessons across four topics.
The existing price remains US$19.90 monthly or US$199 annually. One subscription includes all four topics; active members do not buy courses separately. Knowledge libraries, technology overviews, existing topic calculators, data checklists and self-service diagnostics remain free.
Member lessons are available during an active subscription. Topic courses are currently in English and Simplified Chinese. Custom project analysis, design review and personal consulting require a separate scope and quotation; they are not included in the subscription.
This pathway contains three modules and nine lessons. Each includes technical explanations, a diagram, a teaching case, independent exercises and worked answers. Complete each module output before progressing; existing battery lesson URLs are preserved.
ES1 · Storage fundamentals and physical technologies
Module output: Prepare a service specification and distinguish energy, machine power, site resources and charging constraints.
MODULE LESSON 1
ES1.1 · Storage services and technology selection
A storage project buys a time-dependent service, rather than an inventory alone. Specify the net power at a named meter, uninterrupted duration, response delay, recovery window and protected reserve. Heating, cooling and electrical backup are different services even when all quantities are expressed in MWh.
Calculate the event energy.
Identify the first failed constraint for each device.
Reservoir hydro uses natural inflow; pumped storage consumes electricity to restore water elevation. A combined plant may do both, but its natural-inflow generation is not energy recovered from charging. Define upper and lower operating levels, usable volume, pumping intake and generation outlet before calculating storage.
ES1.3 · Air storage and thermal process boundaries
Compressed air inventory is defined by pressure, temperature, mass and the allowed operating window. A pressure vessel volume alone is not usable electricity. Compression releases heat; expansion cools the gas. The heat balance and minimum pressure determine how much electricity can be returned.
Explain why 70% and 60% are not directly comparable RTE claims.
Calculate A output divided by total stated energy input.
ES2 · Battery engineering, procurement and acceptance
Module output: Prepare a common AC duty, warranty comparison and acceptance evidence register.
MODULE LESSON 1
ES2.1 · What a battery system actually delivers
A storage quotation often lists MW and MWh together, but they answer different questions. This lesson follows energy from the cell to the service meter and separates component ratings from a whole-system operating promise. You will build a duty sheet before deciding whether a battery is large enough.
Explain the roles of the battery, BMS, PCS, auxiliaries and supervisory control.
Reconcile DC nameplate, retained capacity, SOC-window energy and net AC delivery.
Check power and duration independently and identify missing operating evidence.
ES2.2 · Procurement, warranties and comparable quotations
A low price and a long warranty can conceal incompatible service boundaries. This lesson turns a quotation into a traceable set of promises and tests calendar limits against the energy the owner actually plans to deliver.
Build one common procurement scope across suppliers.
Interpret calendar and throughput conditions without predicting failure.
Create an exception register and an acceptance/remedy question list.
A factory test, a commissioning record and a reliable operating service cover different parts of the evidence chain. This lesson develops a practical handover method: define the claim, specify the test and preserve the configuration, limitations and responsible party.
Distinguish component tests, site acceptance and integrated service verification.
Explain how safety evidence and operational capability support separate decisions.
Create a lifecycle record with meaningful review triggers.
Fictional island: electrical critical load 0.5 MW for four hours and useful heat 2 MW_th for six hours. A tank advertises 12 MWh_th. A battery has 2 MWh usable AC but no validated transfer-time evidence.
Prepare separate heat and electricity ledgers.
Explain why nominal tank energy is insufficient evidence.
Fictional six-hour duty: 5 MW net AC. Hydro offers 23.1625 MWh AC and a 5 MW output limit. Battery offers 32 MWh usable AC but a 4 MW converter limit. A proposed hybrid has no agreed dispatch or network evidence.